Dual HD/SD-SDI Digital Auto Signal 2x1 Changeover
Model: 500ACO2-HD/SD
Giá bán: Call
Đặt hàng trước 45 ngày

Dual HD/SD Autochangeover is designed to provide extension to the 5600ACO for HD or SD SDI, DVB-ASI, AES audio, bi-level/tri-level syncs and NTSC/PAL video. The unit can also be operated as a standalone changeover unit with two independent 2X1 switchers. The 500ACO uses latching relays to ensure maximum reliability and minimal disruption in the event of any failure.
Features
    Auto detection of six signal types
    Five modes of operation (including VistaLINK®)
    Auto changeover - two standalone auto changeovers or two link changeovers
    Manual DIP switch control - two independently controlled 2x1 switchers
    GPI Control - two independently GPI controlled 2x1 switchers
    ACO Extension - slave unit of the 5600ACO (requires 5600ACO firmware version 1.2 or higher)
    Support for VistaLINK® monitoring and control
    Fully hot-swappable from front of frame with no BNC disconnect required
    Tally output on Frame Status bus upon loss of input signal for quality monitoring
    Latching relays maintain the current path on loss of power
    VistaLINK® capable for remote monitoring via SNMP (using VistaLINK® PRO) when installed in 500FR frame with 500FC VistaLINK® Frame Controller
Specifications
Serial Video Input
            Standards          SMPTE 292M, SMPTE 259M-A, B, C, D (143 to 540Mb/s), DVB-ASI, bi-level/tri-level syncs or NTSC/PAL video
            Number of Inputs           4
            Connector          BNC per IEC 61169-8 Annex A
            Maximum Cable Length   100m of Belden 1694A or equivalent cable combined input and output
            Return Loss       10dB up to 1.5Gb/s
Serial Video Output
            Number of Outputs         2 passive relay outputs
            Connector          BNC per IEC 61169-8 Annex A
            Maximum Cable Length   100m of Belden 1694A or equivalent cable combined input and output
            DC Offset           0V ±0.5V
            Return Loss       10dB up to 1.5Gb/s
General Purpose Input and Output
            Type
            Inputs   Opto-isolated input with internal pull-up to +5V.
            Outputs Normally 10k internal pull-up to +5V. Ground to rear panel when relay is in active position.
            Connector          Two 3 pin terminal blocks with one ground each.
            Signal Level       +5V nominal
Physical
            Number of Slots 1
Electrical
            Voltage +12V DC
            Power   6 Watts
            EMI/RFI Complies with FCC Part 15 Class A, EU EMC Directive